Environmental & ESS Test Lab
- Home
- Services
- Environmental & ESS Test Lab
- Home
- Service
- Environmental & ESS Test Lab
PEL provides Environmental testing services against the requirements of JSS 55555, MIL Std 810, QM333 and other similar standards.
- Force rating – 600 kgf – sine peak
- – 524 kgf – Random
- Freq. range – 5 Hz to 5000Hz
- Max. Load capacity – 80kgs with ILS
- Vibration axis- X, Y, Z
- g’ – 9.80665m/sec2
- Peak Acceleration = 25 G
- Pulse Duration (D) = 6 m Sec
- Numbers of BUMPS =4000±10
- Temperature Range -40°C to +110°C
- Temperature Control Accuracy ± 5°C
- Ramp Rate- Ambient to -10°C(10°C/Min)
- Ramp Rate- -10°C to -40°C(5°C/Min)
- Test on Ambient temperature to 40°C
- Temp Range only ambient Temp-35°C
- Pressure available – 20PSI
- 7 Salt combination test on Ambient temp
- Temperature Range -40°C to +120°C
- Humidity Range: 20%RH to 97% RH
- Temperature Control Accuracy ± 1°C
- Ramp Rate 1°C per min.
- Temperature Range -40°C to +150°C
- Temperature Control Accuracy ± 1°C
- Ramp Rate 1°C per min
- Altitude Range 66000 Feet i.e. 1.60 in Hg
- Temperature Range -40°C to +150°C
- Temperature Control Accuracy ± 1°C