![Pel-India pel-india](https://pel-india.in/wp-content/uploads/2022/07/59-1.jpg)
- Force rating – 600 kgf – sine peak
- – 524 kgf – Random
- Freq. range – 5 Hz to 5000Hz
- Max. Load capacity – 80kgs with ILS
- Vibration axis- X, Y, Z
- g’ – 9.80665m/sec2
![pel-india](https://pel-india.in/wp-content/uploads/2023/03/bump-Mchine1.jpg)
- Peak Acceleration = 25 G
- Pulse Duration (D) = 6 m Sec
- Numbers of BUMPS =4000±10
![Pel-India pel-india](https://pel-india.in/wp-content/uploads/2022/07/52-1.jpg)
- Temperature Range -40°C to +110°C
- Temperature Control Accuracy ± 5°C
- Ramp Rate- Ambient to -10°C(10°C/Min)
- Ramp Rate- -10°C to -40°C(5°C/Min)
![Pel-India pel-india](https://pel-india.in/wp-content/uploads/2022/07/53-1.jpg)
- Test on Ambient temperature to 40°C
![Pel-India pel-india](https://pel-india.in/wp-content/uploads/2022/07/54-1.jpg)
- Temp Range only ambient Temp-35°C
- Pressure available – 20PSI
![Pel-India pel-india](https://pel-india.in/wp-content/uploads/2022/07/55-1.jpg)
- 7 Salt combination test on Ambient temp
![Pel-India pel-india](https://pel-india.in/wp-content/uploads/2022/07/56-1.jpg)
- Temperature Range -40°C to +120°C
- Humidity Range: 20%RH to 97% RH
- Temperature Control Accuracy ± 1°C
- Ramp Rate 1°C per min.
![pel-india](https://pel-india.in/wp-content/uploads/2023/02/altitude-chamber.jpg)
- Temperature Range -40°C to +150°C
- Temperature Control Accuracy ± 1°C
- Ramp Rate 1°C per min
- Altitude Range 66000 Feet i.e. 1.60 in Hg
![pel-india](https://pel-india.in/wp-content/uploads/2023/02/Thermal-shock-chamber.jpg)
- Temperature Range -40°C to +150°C
- Temperature Control Accuracy ± 1°C